2 tph fire tube boiler pressure tempreture maximum
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.. The fire-tube boiler developed as the third of the four major historical types of boilers: low …Get Price
Fig. (2) Shape of fire-tube 2.1.3 Water-tube boilers: • Water-tube boilers have water running through the tubes and fire or gases of combustion surrounding the tubes. The water tubes are connected into a steam drum at the top and a mud drum at the bottom. The fire is in the Combustion chamber. The boiler design can also beGet Price
Normally when boiler rating is specified as 2 TPH it means 2TPH @F&A 100Deg C, which means the boiler will generate 2 TPH steam when the water is at 100deg C & at atmospheric pressure. So while selecting the boiler the actual consumption @ of available feed water & operating pressure needs to be considered.Get Price
The aim of this report is to design a fire-tube boiler which is compact in shape and can be. utilized in simple process heating plants. Design requirements of the boiler with capaci ty of 2. TPH Get Price
an external furnace and shell-type boiler in a sequence. Fire tube boilers of smaller size are vertical and those of larger size are horizontal. The minimum capacity of a water tube boiler is usually around 5 tph. Combo boilers are generally used for solid fuel firing in lower ranges of up to 30 tph for lower pressures <25 atm . 2.Get Price
1. 10 ton szl series biomass steam boiler. SZL series biomass steam boiler is a double-drum horizontal water tube steam boiler, the steam output of boiler is 2-30 tph, and the steam pressure is range from 1.25 to 2.5Mpa. The boiler is package type boiler. In process steam generating plants, this type of bi-drum boiler is preferred mainlyGet Price
Operating Temperature of Steam boiler: T = 179.9 Celcius * Fluid Specific Volume : v f = 1.1273X10 3 m 3 / kg * Fluid Specific Volume : v g = 0.1944 m 3 / kg *Get Price
7. Boiler feed water d) Pressure measurements for 1. Steam 2. Fuel 3. Combustion air, both primary and secondary 4. Draft e) Water condition 1. Total dissolved solids (TDS) 2. pH 3. Blow down rate and quantity The various parameters that were discussed above can be measured with the instruments that are given in Table 1.1.Get Price
H.P. Boilers upto 120 TPH at pressure upto 65 Kg / cm2 & Super Heated Temperature upto 500 o C (Also with membrane Wall). 2) H.P. Steam Boilers on coal, husk, bagasse & bio-gas for co-convention with back pressure steam for process.Get Price
2. Because of B&W's constant effort to improve design, equipment supplied may differ slightly from that described above. * Steam capacities shown are saturated steam. Capacities will vary depending on conditions and limitations. Metric Conversions: inches x 25.4 = mm. inches x 2.54 = cm. feet x 0.3048 = m. lb/h x 0.000453 = T/h. lb/h x 0 Get Price
2. ENERGY EFFICIENCY IN BOILERS 11 1. FUELS AND COMBUSTION 1 2.1 Introduction 11 2.2 The heating surfaces in a boiler 11 2.3 Boiler types and classification 12 2.3.1 Fire tube boilers 12 2.3.2 Water tube boilers 12 2.3.3 Packaged boilers 12 2.3.4 Fluidized bed combustion (FBC) boilers 12 2.4 Performance evaluation of boilers 13Get Price
Boiler has the following specifications: capacity 14 TPH, surface area 340 M2, steam pressure 150 psi (10 bar), tube size 3 inches. The flue is corrugated and has diameter more than 4 metres. Comes with mountings, fittings, (2) vertical feed pumps with motors, fan with motor, control panel, (2) 10kl each storage tanks, ductings and chimney.Get Price
BOILER RATING. Rating of boiler can be specified as: 1) F& A 100˚C – From and at 100 Deg Celsius 2) kW Rating 3) Boiler Horsepower (BoHP) 4) MCR – Maximum Continuous Rating F & A 100 ˚C. F & A is the measure of the maximum quantity of steam in kilogram per hour (kg/h) or (lb/hr) that the boiler may generate at atmospheric pressure when supplied with feed water at …Get Price
HVAC Training; This is how a Fire tube Boiler Works - ControlTrends. Contact number: 0086-371-60922096 Clean boiler supplier 4 Ton 1 6Mpa Biomass Fired 4ton-10 ton biomass boiler with steam pressure 1.25mpa-1 2. Single drum water tube and fire tube boiler. 3.Fuel coal,solid fuel. 4.1 ton 2 ton 4 ton 6 Get A QuoteGet Price
What is the tph of a boiler? - QuoraGet Price
2 ton fire tube steam boiler: Steam Temperature: 184℃ Rated steam pressure: 0.7Mpa/1Mpa/1.25Mpa/1.6Mpa/2.45Mpa: Fuel: Oil/gas fired: Feed temperature: 20℃ …Get Price
Capacity express as BTU/hr. KH6Horizontal boiler. 3. Boiler House Power (BHP) KH6Horizontal boiler. The boiler horsepower (Bhp or hp) is a unit of measurement of the boiler output. A Bhp is the amount of energy required to evaporate 34.5 lb / hr (15.7 kg / hr) of steam at atmospheric pressure and a temperature of 212 ℉ (100 ℃).Get Price
55. The limit to reduction of stack temperature in an oil fired boiler is influenced by a) oil temperature b) air temperature c) % carbon in oil d) % sulphur in oil 56. The type of boiler in which water passes through the tubes and hot gases pass outside the tubes is known as; a) water tube b) fire tube c) packaged boiler d) none of the above 57.Get Price
Fire tube or "fire in tube" boilers; contain long steel tubes through which the hot gasses from a furnace pass and around which the water to be converted to steam circulates. (Refer Figure 2.2). Fire tube boilers, typically have a lower initial cost, are more fuel efficient and easier to operate, but they are limited generally to capacities of 25 tons/hr and pressures of 17.5 kg/cm 2.Get Price
Sep 03, 2021 · We increase the economizer and air preheater tube bundle to increase the heating area. At 75t/h boiler, economizer has 21/24 horizontal rows and 80 longitudinal rows, with a total heating area of 906.5m 2. The total heating area of heat pipe air preheater is 877m 2. After renovation to 90t/h, the heating area of economizer reaches 1002m 2.Get Price
2. BOILERS. Srinivas Ch. Download Download PDF. Full PDF Package Download Full PDF Package. This Paper. A short summary of this paper. 33 Full PDFs related to this paper IMPROVING STEAM BOILER OPERATING EFFICIENCY AND MODEL OF WATER TUBE BOILER. By Faysal Azeem. Energy Audit of Boiler: Awash Melkassa Aluminum Sulphate and Sulphuric Acid Get Price
Number and Type of Boiler 5 x 115 TPH, Water tube, Natural Circulation, Natural Gas / Oil Fired Bi-Drum Packaged boiler. Bottom Supported Pressure part arrangement. 1DesignSpecifications of Auxiliary Boiler PARAMETERS UNIT VALUE Boiler Rating [MCR] TPH 115 SteamPressureatMainSteamStop Valve Outlet from minimum Load upto MCR Kg/cm2 (g) 42.32Get Price
Mar 17, 2015 · Steam, Boiler, and Blowdown Pressure are the same. Combustion Efficiency is the % of fuel energy that is directly added to the feedwater and not otherwise lost or used. Blowdown Rate is the % of incoming feedwater mass flow rate that leaves the boiler as a saturated liquid at boiler pressure.Get Price
Rated Working Pressure: 10.54 kg/cm2(g) Type of Boiler : 3 Pass Fire tube Fuel Fired : Fuel Oil Heating surface : m 2 Boiler Specification 3Get Price
Used 2003 120,000 Lb/Hr Nebraska D-Type Watertube Package Boiler Model NSX-G-100, with MAWP of 250 PSIG. Boiler equipped with Low Nox Natural gas burner, Economizer, Stack, Structural Steel, boiler feed water pumps and ancillary equipment. Boiler is in excellent condition, with all available documentation and drawings.Get Price
Sep 27, 2021 · Low Pressure Fire Tube 10 ton Steam Boiler. September 27, 2021. Place of Origin: China Brand Name: ZOZEN 10000kg, 10 tph; Fuel Design: Nature gas, coke oven gas, biogas, liquid propane gas, diesel, heavy oil, light oil, crude oil, Rated steam temperature(℃) Maximum transport size(m) (L×W×H) WNS1-0.7-Y(Q) 1: 0.7: 170: 3.3×1.8×2 Get Price
2. Because of B&W's constant effort to improve design, equipment supplied may differ slightly from that described above. * Steam capacities shown are saturated steam. Capacities will vary depending on conditions and limitations. Metric Conversions: inches x 25.4 = mm. inches x 2.54 = cm. feet x 0.3048 = m. lb/h x 0.000453 = T/h. lb/h x 0 Get Price
Oct 18, 2021 · The water tube boilers produced by ZBG include SZS gas water tube boilers, SZL chain grate boilers (coal or biomass fuel), and the output ranges from 2 t/h to 60 t/h. If you want to know the best prices for 35T/h to 60T/h water tube boilers, please tell us what your fuel is, working pressure, application areas and other information so that we Get Price
an external furnace and shell-type boiler in a sequence. Fire tube boilers of smaller size are vertical and those of larger size are horizontal. The minimum capacity of a water tube boiler is usually around 5 tph. Combo boilers are generally used for solid fuel firing in lower ranges of up to 30 tph for lower pressures <25 atm . 2.Get Price
Miura's EX industrial boilers are incredibly versatile high-pressure steam systems that may be used with natural gas, propane, or #2 fuel oil. The EX offers NOx ratings as low as 30 ppm depending on the model and a compact footprint that occupies 33% less boiler room space than a typical fire tube boiler. Get A QuoteGet Price